VS-2204Available

160 TPD Edible Oil Refinery

EUR 5,000,000

As is, where is, Western Europe. Excludes dismantling, shipping, rebuild and commissioning.

Key facts

TypeComplete edible oil refinery
Capacity160 t/day nominal
Process routePhysical and chemical refining
ManufacturersAlfa Laval, Desmet Ballestra, GEA Westfalia, Sulzer
Year of manufacture2007 to 2015
ConditionRunning condition at decommissioning
LocationWestern Europe
UtilitiesBoiler house, cooling, nitrogen generation included

Equipment by section

Degumming and Neutralisation
ItemQtySpecification
Degumming mixer/reactor skid1Alfa Laval, SS316, jacketed, sized to 160 t/day
High-speed centrifugal separator, degumming duty2Alfa Laval, self-cleaning bowl
Caustic neutralisation reactor1SS316, agitated, 12 m3
Neutralisation centrifugal separator2GEA Westfalia, hermetic
Soapstock holding tank2SS304, 20 m3 each
Prewinterisation
ItemQtySpecification
Prewinterisation crystalliser1Jacketed, glycol-cooled, programmable cooling curve
Plate filter, prewinterisation duty1Automatic plate shift, 60 m2 filtration area
Bleaching
ItemQtySpecification
Vacuum bleacher1Desmet Ballestra, batch/continuous convertible, SS316
Bleaching earth dosing system1Screw-fed, closed system
Bleached oil polishing filter2Vertical leaf filter, precoat
Winterisation
ItemQtySpecification
Winterisation crystallisation tank train3Jacketed, programmable cooling, 15 m3 each
Winterisation filter press1Automatic plate-and-frame, PP plates
Deodorisation
ItemQtySpecification
Deodoriser column, tray type1Desmet Ballestra, thin-film, continuous, high-vacuum
Vacuum generation system1Steam ejector and vacuum pump combination, 5-stage
Heat recovery economiser train1Plate type, integrated with deodoriser feed
Fatty acid distillate scrubber and receiver1SS316, condensing
Utilities
ItemQtySpecification
Package fire-tube steam boiler28 t/h at 10 bar, dual fuel
Thermal fluid heater13 MW, closed loop
Chiller plant, glycol duty1450 kW, screw compressor
Nitrogen generation plant1PSA type, 99.9 percent purity
Cooling tower, induced draught2GEA, 1200 m3/h each
Plant-wide DCS control system1Panel and field instrumentation, drawings included

Gallery